Full View Sight Flow Indicators |
| We specialize in offering a best-in-class Full View Sight Flow Indicators to our valuable patrons. The offered range is acknowledged for feature like blow hole free investment casting body and electo polish finish for better resistance to surface corrosion. These full view sight flow indicator are recommended where maximum visibility is desired on low pressure applications, which is up to 8 kg/cm2. Used in vertical or horizontal lines with a negligible pressure drop, our range is ideal for visual check of the presence, colour & condition of liquid, where there is intermittent flow, partially filled lines or entrained air. Other details: - Glass tubes: Borosilicate buttress
- Nuts-bolts and stud: M.S./S.S. 304, M.S./S.S. 306
- Materials of flanges: WCB/M.S., CF 8/S.S 304, CF 8M/S.S. 316
- Flange standards: A.S.A, 150 RF, A.S.A 300 RF, B.S. 10 table E or F
- Lining (optional): PTFE/PFA/TFE (0.8 TO 1 mm thick)
- Sealing: PTFE (standard)
- Operating temperature: 210° C Max. with PTFE sealing
- Optional sealing material: PTFE envelop with Neoprene insert/viton/silicon
- Flange to flange distance: 100 mm/125 mm/195 mm (+-3 mm)
- Hydraulic test pressure: For size 15 to 50 mm 8 Kg/cm, 2/65 to 100 mm, 5 Kg/cm, 2/150 mm 3 Kg/cm2
|
|
|
|
|
|
|